Scientific data management · Adsorption screening
What Do Tabulated Isotherms Certify?
Sharp Certain Answers to Mixture-Adsorption Screening Queries
Two isotherm tables can be fitted well by many models that disagree about the mixture. We compute what the tables themselves certify, and which measurement would settle the rest.
24 well-fitting model pairs: selectivity 217 to 2,018.
The tables alone certify 178 to 15,497. With the advised N₂ measurements: 421 to 2,810.
“Is S ≥ 300?” goes from undetermined to a certain yes.
From a screening question to a certain answer
Choose a mixture and a target, see which materials certainly pass, and find out what to measure when the tables cannot decide. These are screen recordings of the same workbench you can open below; it runs on real records.
- 1. Ask the questionPick the gas pair, pressure, composition and the selectivity you need.
- 2. Read the certain answersEach material is YES, NO or UNDETERMINED for every isotherm consistent with its tables.
- 3. Settle what is openInspect why a material is undetermined and which measurement would decide it.
Screen materials with certain answers
The workbench evaluates the paper's online stage in your browser: lookups in envelope tables that the Python package compiled from 411 NIST ISODB records. Answers are relative to IAST, the isotherm class, the tolerance and the Henry cap. To certify your own tables, use the Python interface below.
See how far one isotherm can be trusted
Find the measurement that settles a query
Plan a measurement · MP4 · GIF
Abstract
High-throughput materials discovery for energy-intensive chemical separations queries pure-component adsorption repositories through Ideal Adsorbed Solution Theory (IAST) to screen binary mixture selectivity before synthesis or mixed-gas testing. Existing screening pipelines fit a single parametric isotherm per record or compare a small ensemble of fitted equations; however, because IAST integrates spreading pressure down to zero pressure and evaluates the weaker-adsorbing gas beyond its measured pressure window in 59% of real pairs, curves that agree within measurement tolerance on the observed points diverge sharply at query pressures, capturing only 26% of the certified selectivity range and missing 93.1% of held-out measurements at 5 to 10× extrapolation. We reformulate mixture screening as certain-answer query processing over infinite-dimensional nonparametric site-mixture cones, comprising a shape-only concave hinge class Ch and a completely monotone Langmuir-site Stieltjes class CL constrained solely by pointwise measurement tolerance ε and a zero-pressure Henry slope cap H = κKmin. We prove an Envelope Reduction Theorem that decouples bivariate mixture equilibrium optimization without loss into two univariate spreading-pressure envelopes realized by at most n + 2 sites per record, and establish two scaling laws: an Extrapolation-Horizon Law showing that relative uncertainty diverges at ρ = Θ(1/ε) (32,308 evaluations collapse onto a universal master curve with R2 = 0.91), and a Log-Henry Law showing that low-pressure slope ambiguity scales as Θ(q1− ln H). We build IsoCert, a two-phase screening engine that admits records via a misfit-floor linear program and compiles continuum-certified column-generation envelopes offline into compact monotone lookup tables, answering online selectivity-interval queries in 0.15 ms (8118× faster than direct LP solving) and threshold queries (YES, NO, or UNDETERMINED) in 25 µs from four table interpolations while computing critical Henry caps κ⋆ and one-step lookahead measurement advice on demand. Experiments across 13,183 NIST ISODB isotherms and 1,930 real gas pairs demonstrate that IsoCert covers 97.0% of held-out points (≤ 10 bar) and 96.5% at 5 to 10× extrapolation (1.9× tighter than shape-only envelopes), achieves 100.0% coverage with 0 false decisions across 1,592 certified threshold answers under cap-respecting truth, and resolves 68% of undetermined pairs to target precision in a median of 2 lookahead measurements.
Overview
Materials for gas separation are screened by pairing two pure-gas isotherm tables and solving IAST for the mixture selectivity. Practice fits one model per table. The mixture calculation, however, reads each isotherm outside its measured window: it integrates from zero pressure, and it evaluates the weaker gas at a pressure that exceeds the last measured point in 59% of the 1,930 real pairs we analysed. Models that agree on the window disagree there, so fit quality does not determine the answer.
We replace the single fit by the set of all isotherms consistent with a table and ask what holds for every member. A threshold query then has a certain answer: YES, NO, or UNDETERMINED, together with the exact interval of possible selectivities.
Method
A record with points (pi, qi), tolerance ei = ε maxj qj and Henry slope cap H = κKmin defines a cone of site mixtures q(p) = c0p + ∫ φb(p) dμ(b) with c0 ≥ 0, μ ≥ 0, data boxes qi − ei ≤ q(pi) ≤ qi + ei and q′(0) ≤ H. Langmuir sites φb(p) = p/(1 + bp) give the Langmuir-site Stieltjes class CL, which contains single- and multi-site Langmuir, Tóth and UNILAN isotherms with finite Henry constants; hinge sites min(p, 1/b) give the shape-only class Ch of all nonnegative, nondecreasing, concave isotherms. The dual-site Langmuir set C2 ⊆ CL ⊂ Ch brackets them from inside. The spreading pressure Π(r) is linear in the site measure, so its upper and lower envelopes U(r), L(r) over a class are linear semi-infinite programs. The Envelope Reduction Theorem uses the monotonicity of the IAST root in the two spreading pressures: the exact selectivity interval over both classes needs only these per-record envelopes,
S⁺ = IAST(UA, LB), S⁻ = IAST(LA, UB).
Both ends of [S⁻, S⁺] are attained by members of the classes, each envelope value by an isotherm with at most n + 2 sites, and a threshold query S ≥ τ is decided from four envelope values. Two laws bound what a table can certify. The Extrapolation-Horizon Law: relative uncertainty stays of order ε inside the measured window but becomes of order one at the extrapolation ratio ρ = r/Pmax ∼ (1 + 1/c)/ε = Θ(1/ε), where c is the saturation degree of a Langmuir isotherm at Pmax. The Log-Henry Law: below the lowest measured pressure p1, the spreading-pressure width grows as Θ(q1− ln H), so an explicit Henry cap is necessary; each decision reports its critical Henry cap κ⋆, the largest multiplier under which it still holds.
Offline, IsoCert admits a record when its misfit floor ε⋆, the optimum of a linear program, is at most 3%, computes each envelope by column generation with a dual certificate that holds for every site affinity, and compiles the record once into monotone outer-bound tables. Online, it answers a threshold query from four table lookups and an interval query by a scalar root solve on the tables. When a query is undetermined, a one-step lookahead ranks candidate measurements by the certified width they are predicted to leave.
Results
On 607 held-out records measured up to 10 bar, bands computed from a low-pressure prefix of each record cover 97.0% of 12,402 hidden points and 96.5% at 5–10× extrapolation, 1.9× tighter there than shape-only bands. The best-fit model falls within ±3% of only 19.6% of the hidden measurements, and of 6.9% at 5–10× extrapolation. Keeping all dual-site Langmuir parameters within tolerance, instead of one fit, recovers most of this coverage (95.3%); the certified class adds the remaining points and a guarantee.
| Method | ρ ∈ (1, 2] | ρ ∈ (2, 5] | ρ ∈ (5, 10] | all ρ ∈ (1, 10] | ||||
|---|---|---|---|---|---|---|---|---|
| cov. | width | cov. | width | cov. | width | cov. | width | |
| Best-fit model (point) | 62.3 | 1.00 | 19.5 | 1.00 | 6.9 | 1.00 | 19.6 | 1.00 |
| Six-family ensemble | 80.1 | 1.05 | 61.6 | 1.20 | 58.8 | 1.57 | 63.0 | 1.24 |
| Dual-site parameter set | 97.4 | 1.27 | 95.6 | 1.97 | 94.5 | 3.61 | 95.3 | 2.43 |
| Hinge class (shape only) | 99.0 | 1.51 | 98.6 | 3.11 | 99.1 | 6.85 | 98.9 | 4.29 |
| Langmuir-site class (ours) | 98.3 | 1.27 | 97.3 | 2.00 | 96.5 | 3.68 | 97.0 | 2.51 |
| Langmuir-site class, records above 10 bar | 96.0 | 1.20 | 81.8 | 1.76 | 82.0 | 3.13 | 84.2 | 2.14 |
607 Type-I records with Pmax ≤ 10 bar and 12,402 hidden points; last row: stress test on 464 records with Pmax > 10 bar and 7,512 hidden points, outside the Type-I validity range. A point counts as covered inside the band widened by the record's tolerance (ε = 3% of the maximum loading; across 412 groups of replicate measurements, this tolerance covers 97.1% of repeat curves). 95% confidence interval of the 97.0%: 95.5–98.3%. Curated data.
Across 1,930 real pairs and 12 gas separations, the certified interval of ln S has median width 1.25, a factor of 3.5 in selectivity. A six-family ensemble spans 26% of that width, and its spread correlates with fit error at only 0.21 (Spearman); the dual-site parameter set spans a median 96%. At thresholds a factor 2 below and above the best-fit selectivity, IsoCert certifies 66% of pairs as YES and 50% as NO. On 990 synthetic instances with known truth, the interval contains the true selectivity in all 670 instances that respect the Henry cap, with 0 false decisions among 1,592 certified threshold answers. On 100 undetermined pairs, one-step lookahead reaches the target precision for 68% in a median of 2 added measurements, against 7% for adding points inside the measured window. Compiled tables answer an interval query in 0.15 ms (8118× faster than direct LP evaluation) and a threshold query in 25 µs.
Scope and limitations
Answers are certain relative to the binary IAST mixing rule, the stated isotherm class, the tolerance and the Henry cap; they are not prediction intervals for real mixtures. On all 272 binary mixture series in ISODB (2,512 measured points), the certified interval contains the measured selectivity for 60% at the default cap (κ = 10) and 75% at κ = 1000 (a fit ensemble: 24%). Above 10 bar, held-out coverage of the Langmuir-site class drops to 84.2%. Over all 990 synthetic instances, including those whose Henry constant violates the cap, the Langmuir-site class covers 95.1%, and 1.8% of its calls at a 1.25× margin (1.3% at 2×) are false. The dual-site parameter set reaches a median 96% of the certified width, so most of the ambiguity is already present in ordinary two-site models; the certified class adds the outer guarantee. The measurement advice is a myopic one-step heuristic, not an optimal experimental design. Certificates hold up to double-precision rounding; verified arithmetic is not used.
Implementation
The repository provides the Python package isocert (NumPy and SciPy, no GPU), examples, tests and the workbench source. A record needs only its pressures and loadings.
git clone https://github.com/OliverDOU776/What-Do-Tabulated-Isotherms-Certify-.git
cd What-Do-Tabulated-Isotherms-Certify-
python -m pip install .
python examples/quickstart.py
from isocert import Record, interval, decide
co2 = Record(p_co2, q_co2) # pressures (bar), loadings (mmol/g)
n2 = Record(p_n2, q_n2)
iv = interval(co2, n2, P=1.0, y=0.15) # certified [S-, S+]
print(iv.S_lo, iv.S_hi, decide(co2, n2, P=1.0, y=0.15, tau=50))
Citation
@misc{wang2026isotherms,
title = {What Do Tabulated Isotherms Certify? Sharp Certain Answers to Mixture-Adsorption Screening Queries},
author = {Wang, Zijia and Hong, Haoliang and Li, Xuhui and Bai, Jingyang and Nie, Binjian},
year = {2026},
url = {https://github.com/OliverDOU776/What-Do-Tabulated-Isotherms-Certify-}
}