Scientific data management · Adsorption screening

What Do Tabulated Isotherms Certify?
Sharp Certain Answers to Mixture-Adsorption Screening Queries

Two isotherm tables can be fitted well by many models that disagree about the mixture. We compute what the tables themselves certify, and which measurement would settle the rest.

The idea in sixteen seconds. Drawing is schematic; every number is computed from real records of CO₂ and N₂ on zeolite 13X at 298 K (source), chosen for illustration. See the data behind it.

24 well-fitting model pairs: selectivity 217 to 2,018.
The tables alone certify 178 to 15,497. With the advised N₂ measurements: 421 to 2,810.
“Is S ≥ 300?” goes from undetermined to a certain yes.

From a screening question to a certain answer

Choose a mixture and a target, see which materials certainly pass, and find out what to measure when the tables cannot decide. These are screen recordings of the same workbench you can open below; it runs on real records.

  1. 1. Ask the questionPick the gas pair, pressure, composition and the selectivity you need.
  2. 2. Read the certain answersEach material is YES, NO or UNDETERMINED for every isotherm consistent with its tables.
  3. 3. Settle what is openInspect why a material is undetermined and which measurement would decide it.

Screen materials with certain answers

Your result: a shortlist that holds for every isotherm consistent with the data, a list of materials that a best-fit screen would have passed without support, and a CSV of both. In the recording, a best-fit screen shortlists 33 of 90 CO₂/N₂ pairs; 14 of them are not certain.

Open the screening workbench · MP4 · GIF

The workbench evaluates the paper's online stage in your browser: lookups in envelope tables that the Python package compiled from 411 NIST ISODB records. Answers are relative to IAST, the isotherm class, the tolerance and the Henry cap. To certify your own tables, use the Python interface below.

See how far one isotherm can be trusted

Only the low-pressure tenth of a real record is visible. Six models fit it and then disagree; the certified band shows the range the visible points support. Reveal the hidden measurements to check both, including a record where the band misses.

Try an extrapolation · MP4 · GIF

Find the measurement that settles a query

Both records stop at 1 bar and the query is undetermined. The advice points to the weaker gas above 1 bar. Adding the real CO₂ points changes nothing; adding the real N₂ points makes the answer certain.

Plan a measurement · MP4 · GIF

Abstract

High-throughput materials discovery for energy-intensive chemical separations queries pure-component adsorption repositories through Ideal Adsorbed Solution Theory (IAST) to screen binary mixture selectivity before synthesis or mixed-gas testing. Existing screening pipelines fit a single parametric isotherm per record or compare a small ensemble of fitted equations; however, because IAST integrates spreading pressure down to zero pressure and evaluates the weaker-adsorbing gas beyond its measured pressure window in 59% of real pairs, curves that agree within measurement tolerance on the observed points diverge sharply at query pressures, capturing only 26% of the certified selectivity range and missing 93.1% of held-out measurements at 5 to 10× extrapolation. We reformulate mixture screening as certain-answer query processing over infinite-dimensional nonparametric site-mixture cones, comprising a shape-only concave hinge class Ch and a completely monotone Langmuir-site Stieltjes class CL constrained solely by pointwise measurement tolerance ε and a zero-pressure Henry slope cap H = κKmin. We prove an Envelope Reduction Theorem that decouples bivariate mixture equilibrium optimization without loss into two univariate spreading-pressure envelopes realized by at most n + 2 sites per record, and establish two scaling laws: an Extrapolation-Horizon Law showing that relative uncertainty diverges at ρ = Θ(1/ε) (32,308 evaluations collapse onto a universal master curve with R2 = 0.91), and a Log-Henry Law showing that low-pressure slope ambiguity scales as Θ(q1− ln H). We build IsoCert, a two-phase screening engine that admits records via a misfit-floor linear program and compiles continuum-certified column-generation envelopes offline into compact monotone lookup tables, answering online selectivity-interval queries in 0.15 ms (8118× faster than direct LP solving) and threshold queries (YES, NO, or UNDETERMINED) in 25 µs from four table interpolations while computing critical Henry caps κ⋆ and one-step lookahead measurement advice on demand. Experiments across 13,183 NIST ISODB isotherms and 1,930 real gas pairs demonstrate that IsoCert covers 97.0% of held-out points (≤ 10 bar) and 96.5% at 5 to 10× extrapolation (1.9× tighter than shape-only envelopes), achieves 100.0% coverage with 0 false decisions across 1,592 certified threshold answers under cap-respecting truth, and resolves 68% of undetermined pairs to target precision in a median of 2 lookahead measurements.

Overview

Materials for gas separation are screened by pairing two pure-gas isotherm tables and solving IAST for the mixture selectivity. Practice fits one model per table. The mixture calculation, however, reads each isotherm outside its measured window: it integrates from zero pressure, and it evaluates the weaker gas at a pressure that exceeds the last measured point in 59% of the 1,930 real pairs we analysed. Models that agree on the window disagree there, so fit quality does not determine the answer.

Left: nitrogen isotherm on zeolite 13X measured up to 1 bar, six fitted models and the certified band, with the pressure range that IAST reads far beyond the last point. Right: selectivities of 24 pairs of fitted models from 217 to 2,018, the certified interval 178 to 15,497 (undetermined for a target of 300), and the interval 421 to 2,810 after adding nitrogen points up to 10 bar (yes).
The opening example in data. CO₂ and N₂ on zeolite 13X at 298 K from NIST ISODB (source), chosen for illustration. Left: the N₂ record up to 1 bar, six fits within tolerance, the certified band, and the pressures at which IAST reads the record. Right: selectivities of the 24 pairs of fitted models, the certified interval from the tables, and the interval after the N₂ points measured up to 10 bar are returned. Operate this example.

We replace the single fit by the set of all isotherms consistent with a table and ask what holds for every member. A threshold query then has a certain answer: YES, NO, or UNDETERMINED, together with the exact interval of possible selectivities.

Method

A record with points (pi, qi), tolerance ei = ε maxj qj and Henry slope cap H = κKmin defines a cone of site mixtures q(p) = c0p + ∫ φb(p) dμ(b) with c0 ≥ 0, μ ≥ 0, data boxes qi − ei ≤ q(pi) ≤ qi + ei and q′(0) ≤ H. Langmuir sites φb(p) = p/(1 + bp) give the Langmuir-site Stieltjes class CL, which contains single- and multi-site Langmuir, Tóth and UNILAN isotherms with finite Henry constants; hinge sites min(p, 1/b) give the shape-only class Ch of all nonnegative, nondecreasing, concave isotherms. The dual-site Langmuir set C2 ⊆ CL ⊂ Ch brackets them from inside. The spreading pressure Π(r) is linear in the site measure, so its upper and lower envelopes U(r), L(r) over a class are linear semi-infinite programs. The Envelope Reduction Theorem uses the monotonicity of the IAST root in the two spreading pressures: the exact selectivity interval over both classes needs only these per-record envelopes,

S⁺ = IAST(UA, LB), S⁻ = IAST(LA, UB).

Both ends of [S⁻, S⁺] are attained by members of the classes, each envelope value by an isotherm with at most n + 2 sites, and a threshold query S ≥ τ is decided from four envelope values. Two laws bound what a table can certify. The Extrapolation-Horizon Law: relative uncertainty stays of order ε inside the measured window but becomes of order one at the extrapolation ratio ρ = r/Pmax ∼ (1 + 1/c)/ε = Θ(1/ε), where c is the saturation degree of a Langmuir isotherm at Pmax. The Log-Henry Law: below the lowest measured pressure p1, the spreading-pressure width grows as Θ(q1− ln H), so an explicit Henry cap is necessary; each decision reports its critical Henry cap κ⋆, the largest multiplier under which it still holds.

Offline, IsoCert admits a record when its misfit floor ε⋆, the optimum of a linear program, is at most 3%, computes each envelope by column generation with a dual certificate that holds for every site affinity, and compiles the record once into monotone outer-bound tables. Online, it answers a threshold query from four table lookups and an interval query by a scalar root solve on the tables. When a query is undetermined, a one-step lookahead ranks candidate measurements by the certified width they are predicted to leave.

Results

On 607 held-out records measured up to 10 bar, bands computed from a low-pressure prefix of each record cover 97.0% of 12,402 hidden points and 96.5% at 5–10× extrapolation, 1.9× tighter there than shape-only bands. The best-fit model falls within ±3% of only 19.6% of the hidden measurements, and of 6.9% at 5–10× extrapolation. Keeping all dual-site Langmuir parameters within tolerance, instead of one fit, recovers most of this coverage (95.3%); the certified class adds the remaining points and a guarantee.

Held-out extrapolation on real ISODB records. Coverage (%) of hidden points and median band ratio qhi/qlo by extrapolation ratio ρ = p/Pcut beyond the visible prefix.
Methodρ ∈ (1, 2]ρ ∈ (2, 5]ρ ∈ (5, 10]all ρ ∈ (1, 10]
cov.widthcov.widthcov.widthcov.width
Best-fit model (point)62.31.0019.51.006.91.0019.61.00
Six-family ensemble80.11.0561.61.2058.81.5763.01.24
Dual-site parameter set97.41.2795.61.9794.53.6195.32.43
Hinge class (shape only)99.01.5198.63.1199.16.8598.94.29
Langmuir-site class (ours)98.31.2797.32.0096.53.6897.02.51
Langmuir-site class, records above 10 bar96.01.2081.81.7682.03.1384.22.14

607 Type-I records with Pmax ≤ 10 bar and 12,402 hidden points; last row: stress test on 464 records with Pmax > 10 bar and 7,512 hidden points, outside the Type-I validity range. A point counts as covered inside the band widened by the record's tolerance (ε = 3% of the maximum loading; across 412 groups of replicate measurements, this tolerance covers 97.1% of repeat curves). 95% confidence interval of the 97.0%: 95.5–98.3%. Curated data.

Paper figure 1: a tabulated record with six low-pressure points; six fitted families agree on the measured points and fan out in the unobserved query zone, while the certified envelope covers the held-out points; fitted models give contradictory screening calls, while certified intervals separate YES, NO and UNDETERMINED materials; bar chart of coverage at 5 to 10 times extrapolation and on mixture ground truth by method.
Why fit-then-query screening fails, and what the tables certify. Left: from a tabulated pure-gas record (ISODB 10.1039/c3ra46240d, six low-pressure points) and a 15:85 CO₂/N₂ query at 1 bar with target S ≥ 50, six parametric families agree on the measured points but fan out by 2.4× in the unobserved query zone and give contradictory calls on UiO-66 (dual-site Langmuir 75.8, a false YES; Langmuir 12.6, NO). Certified intervals separate YES for TpPA-1 [56.8, 247.5] and NO for UiO-66 [14.7, 46.1] from UNDETERMINED for Mg-MOF-74 [39.5, 260.1]. Right: coverage at 5–10× extrapolation on 607 held-out records and on ground-truth mixtures: IsoCert (CL) 96.5% and 100.0% (670 cap-respecting instances, 0 false decisions across 1,592 certified answers), best-AIC point fits 6.9% and 24.6%, six-family ensembles 58.8% and 58.6%. Figure 1 of the paper.

Across 1,930 real pairs and 12 gas separations, the certified interval of ln S has median width 1.25, a factor of 3.5 in selectivity. A six-family ensemble spans 26% of that width, and its spread correlates with fit error at only 0.21 (Spearman); the dual-site parameter set spans a median 96%. At thresholds a factor 2 below and above the best-fit selectivity, IsoCert certifies 66% of pairs as YES and 50% as NO. On 990 synthetic instances with known truth, the interval contains the true selectivity in all 670 instances that respect the Henry cap, with 0 false decisions among 1,592 certified threshold answers. On 100 undetermined pairs, one-step lookahead reaches the target precision for 68% in a median of 2 added measurements, against 7% for adding points inside the measured window. Compiled tables answer an interval query in 0.15 ms (8118× faster than direct LP evaluation) and a threshold query in 25 µs.

Paper figure 4: the closed-form extrapolation-horizon witness against exact LP envelopes for four tolerances, the histogram of the log-Henry slope ratio on 857 real records below its ceiling of 1, and the collapse of 32,308 real band points against the dimensionless horizon.
The two laws against computed envelopes. (a) Law 1: certified lower envelope relative to the linear limit for tolerances ε of 0.5%, 1%, 2% and 4%; exact LP values (circles) match the closed-form curves (lines) with median ratio 1.0000. (b) Law 2: the empirical log-Henry slope (dU/d ln H)/c0 on 857 ISODB records stays below the ceiling 1 (median 0.9920, IQR 0.924–0.9999). (c) Collapse of 32,308 held-out band points against log10[ε(ρ − 1)]: slope 0.81, R2 = 0.91 (R2 = 0.73 for unscaled ρ). Figure 4 of the paper.

Scope and limitations

Answers are certain relative to the binary IAST mixing rule, the stated isotherm class, the tolerance and the Henry cap; they are not prediction intervals for real mixtures. On all 272 binary mixture series in ISODB (2,512 measured points), the certified interval contains the measured selectivity for 60% at the default cap (κ = 10) and 75% at κ = 1000 (a fit ensemble: 24%). Above 10 bar, held-out coverage of the Langmuir-site class drops to 84.2%. Over all 990 synthetic instances, including those whose Henry constant violates the cap, the Langmuir-site class covers 95.1%, and 1.8% of its calls at a 1.25× margin (1.3% at 2×) are false. The dual-site parameter set reaches a median 96% of the certified width, so most of the ambiguity is already present in ordinary two-site models; the certified class adds the outer guarantee. The measurement advice is a myopic one-step heuristic, not an optimal experimental design. Certificates hold up to double-precision rounding; verified arithmetic is not used.

Implementation

The repository provides the Python package isocert (NumPy and SciPy, no GPU), examples, tests and the workbench source. A record needs only its pressures and loadings.

Quickstart
git clone https://github.com/OliverDOU776/What-Do-Tabulated-Isotherms-Certify-.git
cd What-Do-Tabulated-Isotherms-Certify-
python -m pip install .
python examples/quickstart.py
Certify a target on your own tables
from isocert import Record, interval, decide

co2 = Record(p_co2, q_co2)                    # pressures (bar), loadings (mmol/g)
n2 = Record(p_n2, q_n2)
iv = interval(co2, n2, P=1.0, y=0.15)         # certified [S-, S+]
print(iv.S_lo, iv.S_hi, decide(co2, n2, P=1.0, y=0.15, tau=50))

Repository and documentation · Paper PDF

Citation

BibTeX
@misc{wang2026isotherms,
  title  = {What Do Tabulated Isotherms Certify? Sharp Certain Answers to Mixture-Adsorption Screening Queries},
  author = {Wang, Zijia and Hong, Haoliang and Li, Xuhui and Bai, Jingyang and Nie, Binjian},
  year   = {2026},